Jeffrey Siegel, Ph.D.

Co-Principal Investigator, IGERT: Indoor Environmental Science and Engineering – An Emerging Frontier


Courses Awards Papers Conference Papers Dissertation


 

Associate Professor

J. Neils Thompson Centennial Teaching Fellow in Civil Engineering

Department of Civil, Architectural, and Environmental Engineering

Architectural Engineering Program, ECJ 5.2

The University of Texas at Austin

1 University Station C1752

Austin, TX 78712-1076

 

Phone: (512) 471-2410

Fax: (512) 471-3191

Lab: (512) 471-9688

jasiegel@mail.utexas.edu

 

 

B.S., Swarthmore College, Engineering
M.S., U.C. Berkeley, Mechanical Engineering
Ph.D., U.C. Berkeley, Mechanical Engineering

Dr. Jeffrey Siegel received his Ph.D. from Berkeley in Mechanical Engineering.  His research interests include design of energy-efficient and healthy buildings, filtration and particle control technologies, indoor air quality, ventilation, and indoor particle dynamics.

Courses

ARE 383: Advanced Energy Efficient and Healthy Buildings Spring 2012
ARE 346N: Building Environmental Systems Fall 2011
ARE 370: Design of Energy Efficient and Healthy Buildings Fall 2011
ARE 389T/CE389T: Indoor Air Quality: Transport and Control  Spring 2011

Awards

Recent Papers

These papers are provided for educational purposes only.  They are typically copyright by the publication in which they appeared.  Contact the publication directly for permission to use.

  1. Stephens, B., Novoselac, A., Siegel J.A. 2011. Operation characteristics of residential and light-commercial air-conditioning systems in a hot and humid climate zone. Building and Environment, 46(10), 1972-1983.
  2. Waring, M.S., Wells, J.R,  Siegel, J.A. 2011. Secondary Organic Aerosol Formation from Ozone Reactions with Single Terpenoids and Terpenoid Mixtures. Atmospheric Environment, 45(25), 4235-4242.
  3. Waring, M.S. and  Siegel, J.A. 2011. Indoor air quality implications of using ion generators in residences. Indoor Air, 21(3), 267-276.
  4. Gall, E.T., Corsi, R., Siegel, J.A. 2011. Barriers and Opportunities for Passive Removal of Indoor Ozone. Atmospheric Environment, 45(19), 3338-3341.
  5. Noris, F., Siegel. J.A., Kinney, K.A. 2011. Evaluation of HVAC filters as a sampling mechanism for indoor microbial communitiesAtmospheric Environment, 45, 338-346.
  6. Hun D.E., Corsi R. L., Morandi M.T., Siegel J.A. 2011. Automobile proximity and indoor residential concentrations of BTEX and MTBE. Building and Environment, 46, 45-53.
  7. Peschiera, G. Taylor, J.T., Siegel J.A.  2010.  Response-Relapse Patterns of Building Occupant Electricity Consumption Following Exposure to Personal, Contextualized and Occupant Peer Network Utilization DataEnergy and Buildings, 42, 1329–1336.
  8. Hun D.E., Corsi R. L., Morandi M.T., Siegel J.A. 2010. Formaldehyde in Residences:  Long-Term Indoor Concentrations and Influencing Factors. Indoor Air, 20(3), 196-203
  9. Waring, M.S., Siegel, J.A. 2010. The Influence of HVAC Systems on Indoor Secondary Organic Aerosol Formation. ASHRAE Transactions, 116(1), 273-294.
  10. Stephens, B., Novoselac, A., Siegel J.A. 2010. Energy Implications of Filters in Residential and Light-Commercial Buildings. ASHRAE Transactions, 116(1), 346-357
  11. Stephens, B., Novoselac, A., Siegel J.A.  2010. The Effects of Filtration on Pressure Drop and Energy Consumption in Residential HVAC Systems. HVAC&R Research, 16(3), 273-294.
  12. Kunkel, D. A., Gall, E. T., Siegel, J.A., Novoselac, A., Morrison, G.C,Corsi, R.L. 2010. Passive Reduction of Human Exposure to Indooor Ozone. Building and Environment, 45(2), 445–452.
  13. Hun D.E., Siegel J.A., Morandi M.T., Stock, T.H., Corsi R. L. 2009. Cancer risk disparities between Hispanic and non-Hispanic White populations:  The role of exposure to indoor air pollution. Environmental Health Perspectives117 (12), 1925-1931.
  14. Noris, F.,  Siegel, J.A.,  Kinney, K.A. 2009. Biological and Chemical Contaminants in HVAC Filter DustASHRAE Transactions, 115(2), 484-491.
  15. Mukai, C., Siegel, J.A., Novoselac, A. 2009. Impact of Airflow Characteristics on Particle Resuspension from Indoor Surfaces. Aerosol Science and Technology, 43(10), 1022-1032.
  16. Novoselac, A., Siegel, J.A. 2009. Effective Positioning of Portable Air Cleaning Devices in Multizone Residential Buildings. Building and Environment, 44(12), 2348-2356.
  17. VerShaw, J., Siegel, J.A., Chojnowski, D.B., Nigro, P.J.  Implications of Filter Bypass.  ASHRAE Transactions, 115(1), 191-198.
  18. Chojnowski, D.B. Nigro, P.J. Siegel, J.A.,  Kosar. D.A.  Laboratory Measurements to Quantify the Effect of Bypass on Filtration Efficiency.  ASHRAE Transactions, 115(1), 199-207
  19. Rim, D., Siegel, J., Spinhirine, J., Webb, A., McDonald-Buller, E. 2008. Characteristics of Cabin Air Quality in School Buses in Central TexasAtmospheric Environment, 42, 6453-6464.
  20. Waring, M., Siegel,  J.A., Corsi, R. 2008. Ultrafine particle removal and generation by portable air cleaners. Atmospheric Environment , 42, 5003-5014.
  21. Waring, M., Siegel, J. A. 2008. Particle loading rates for HVAC filters, heat exchangers, and ducts. Indoor Air, 18, 209-224.
  22. Corsi, R. L., Siegel, J. A., Chiang C. 2008. Particle resuspension during the use of vacuum cleaners on residential carpet. Journal of Occupational and Environmental Hygiene, 5, 232-238.
  23. Waring, M., Siegel, J.A. 2007. An evaluation of the indoor air quality in bars before and after a smoking ban in Austin, TX. Journal of Exposure Science and Environmental Epidemiology, 17, 260-268
  24. Corsi, R. L., Siegel, J., Karamalegos, A., Simon, H., Morrison, G. C. 2007. Personal reactive clouds: Introducing the concept of near-head chemistry. Atmospheric Environment, 41, 3161-3165.
  25. Zhao, P., Siegel, J. A., Corsi, R. L. 2007. Ozone removal by HVAC filters. Atmospheric Environment, 41, 3151-3160.
  26. Francisco, P. Siegel, J., Palmiter, L., Davis, B. 2006.  Measuring Residential Duct Efficiency with the Short-Term Coheat Test MethodologyEnergy and Buildings, 38, 1076-1083.
  27. Ward, M., Siegel, J.A. 2005. Modeling Filter Bypass: Impact on Filter EfficiencyASHRAE Transactions. 111(2), 1091-1100.
  28. Ward, M., Siegel, J.A., Corsi,  R.L. 2005. The effectiveness of stand alone air cleaners for shelter-in-place. Indoor Air, 15(2): 127-  134.

  29. Siegel, J.A., Nazaroff W.W. 2003. Predicting particle deposition on HVAC heat exchangers. Atmospheric Environment, 37, 5587-5596.
  30. Siegel, J.A.,  McWilliams, J., Walker, I.  2003.  Comparison Between Predicted Duct Effectiveness from Proposed ASHRAE Standard 152P and Measured Field Data for Residential Forced Air Cooling SystemsASHRAE Transactions, 109(1), 503-512.
  31. Siegel, J., Wray, C. P. 2002. An Evaluation of Superheat-Based Refrigerant Charge Diagnostics for Commissioning Residential Cooling Systems. ASHRAE Transactions, 108(2), 965-975.


Accepted for Publication
(Journals often provide preprints on their webpage or contact me for a draft copy)
Cros, C., Morrison, G.C., Siegel, J.A., Corsi, R.L. Long-term performance of passive materials for removal of ozone from indoor air. Accepted to Indoor Air. DOI: 10.1111/j.1600-0668.2011.00734.x.
Stephens, B.R., Siegel J.A. Comparison of Test Methods for Determining Particle Removal Efficiency of Filters in Residential and Light-commercial Central HVAC Systems.  Accepted to Aerosol Science and Technology.
Stephens, B.R., Gall, E.T., Siegel J.A. Measuring the penetration of ambient ozone into residential buildings.  Accepted to Environmental Science and Technology.

Submitted (under review - contact me for a draft copy)



Conference Papers

  1. Cros, C., Morrison, G.C., Siegel, J.A., Corsi, R.L. 2011. Passive Removal Of Indoor Ozone By Green Building Materials. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 103.
  2. Stephens, B.R., Gall, E.T., Siegel, J.A. 2011. A Method For Measuring Ozone Penetration Through The Building Envelope. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 148.
  3. Gall, E.T., Corsi, R., Siegel, J.A. 2011. Determination Of Ozone Reaction Probabilities With Porous Materials. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 175.
  4. Hun D.E., Corsi R. L., Morandi M.T., Siegel J.A. 2011. Automobile Proximity And Indoor Residential Concentrations Of BTEX And MTBE.  Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 592.
  5. Taylor Lange , S. C., Cros, C., Juenger, M. C. G., Siegel, J.A., Poppendieck, D. 2011. The Role of Material Porosity on Ozone Uptake of Metakaolin-concrete Surfaces. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 933.
  6. Stephens, B.R., Siegel, J.A.  2011. Comparison Of HVAC Filter Test Methods For Particle Removal Efficiency.  Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 945.
  7. Waring, M.S., Siegel, J.A. 2011. Yields of Secondary Organic Aerosol from Reactions between Ozone and Surface-Adsorbed d-Limonene. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 958.
  8. Siegel, J.A. 2011. Energy Implications of Residential Particle Control Technologies. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 1003.
  9. Rhodes, J.D., Nirlo, E. Srebric, J., Siegel, J.A. 2011. Indoor Air Quality In Retail Buildings: A Review. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 1008.
  10. Taylor Lange , S., Juenger, M. C. G., Siegel, J.A. Indoor Radon Exhalation Rates From Concrete With Fly Ash. Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 1015.
  11. Gunther, M., Rhodes, J.D., Morrison, G.C., Siegel, J.A. A Laboratory Method For Measuring The Ozone Emission From In-duct Air Cleaners.  Indoor Air 2011: Proceedings of the 12th International Conference on Indoor Air and Climate, paper ID 1069.
  12. Gall, E.T., Siegel, J.A., Corsi, R.L. 2011. Zero-Energy Removal of Ozone in Residences. ASHRAE Transactions, 117(1), LV-11-C050, 411-418.
  13. Boor, B.E., Siegel, J.A., Novoselac, A. 2011. Development of an Experimental Methodology to Determine Monolayer and Multilayer Particle Resuspension from Indoor Surfaces. ASHRAE Transactions, 117(1), LV-11-C053, 434-441.
  14. Jackson, M., Aldred, J., Canady, J., Corsi, R.L, Siegel, J.A. 2010. The potential role of toilets as a vector for transmission of infectious disease. IAQVEC 2010: Proceedings of the 7th International Conference on Indoor Air Quality, Ventilation, and Energy Conservation, paper ID 87-112, 1-8
  15. Cros, C., Gall, E.T., Siegel, J.A., Morrison, G.C., and Corsi, R.L. 2009. Removal of Indoor Ozone with Reactive Materials: Preliminary Results and Implications. Proceedings of Healthy Buildings 2009, Paper ID 141, 1-4.
  16. Gall, E. T., Cros, C., Corsi, R.L. and Siegel, J.A. 2009. Time-scale analysis for reactive deposition of ozone via passive reactive materials (PRMs)Proceedings of Healthy Buildings 2009, Paper ID 336, 1-4.
  17. Hun D.E., Siegel J.A., Morandi M.T., and Corsi R. L. 2009. Effect of ventilation rates on indoor formaldehyde concentrations in
    residences
    . Proceedings of Healthy Buildings 2009, Paper ID 695, 1-4.
  18. Noris, F., Kinney, K.A. and Siegel. J.A. 2009. HVAC filters as “passive” samplers: Fate analysis of indoor particles. Proceedings of Healthy Buildings 2009, Paper ID 535, 1-4.
  19. Siegel J., 2009. Do forced air HVAC systems have a role in healthy homes? Proceedings of Healthy Buildings 2009, Paper ID 680, 1-4
  20. Stephens, B., Novoselac, A., and Siegel J.A. 2009. Impacts of HVAC Filtration on Air-Conditioner Energy Consumption in Residences. Proceedings of Healthy Buildings 2009, Paper ID 474, 1-4.
  21. Waring M.S. and Siegel J.A. 2009. The influence of HVAC systems on secondary organic aerosol formation. Proceedings of Healthy Buildings 2009, Paper ID 727, 1-4.
  22. Hun D.E., Morandi M.T., Corsi R. L., Siegel J.A., and Stock, T.H. 2009. “Exposure and Risk Disparities Between Mexican-American and White Populations in Houston.” Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 935, 1-8.
  23. Lohaus J.H., Novoselac A., and Siegel J.A. “Particle Resuspension from Indoor Flooring Materials.” Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 342, 1.
  24. Kang Y.K., Novoselac A., and Siegel J.A., “Effective Positioning of Portable Air Cleaning Devices in Multizone Residential Buildings.” Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 644, 1-8.
  25. Noris F., Kinney K.A., and Siegel J.A., “Comparison of Dust from HVAC Filters, Indoor Surfaces, and Indoor Air.Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 553, 1-8.
  26. Shelton G., Zhao, P.,  Corsi R. L., and Siegel J.A., “Ozone removal on HVAC filters: Underlying mechanisms, model development, and parameter estimation.” Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 271, 1-8.
  27. Siegel J.A., Chojnowski D.B., Nigro P. J., and Kosar, D. “HVAC Filter Bypass Modelling and Experimental Validation.” Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 343, 1-7. 
  28. Waring M.S., Siegel J.A., Corsi R. L., and Morrison G. “Do surface reactions influence formation of secondary organic aerosol?Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 603, 1.
  29. Waring M.S. and Siegel J.A. “Indoor Air Quality Implications of Using Ion Generators in Residences.Indoor Air 2008: Proceedings of the 11th International Conference on Indoor Air and Climate, paper ID 598, 1-8.
  30. Kunkel, D. A., Corsi, R.L, Morrison, G.C, Novoselac A., and Siegel, J.  “Passive Ozone Control Through Use of Reactive Indoor Wall and Ceiling Materials.Proceedings of the Air and Waste Management Association 2008 Annual Meeting, paper ID 715, 1-12.
  31. Siegel J., Waring M., Yu X., and Corsi R., 2007.  “Do Ion Generators Have A Role In Sustainable Indoor Environments?”  ASHRAE IAQ 2007.
  32. Siegel, J.A., Waring, M.S., Yu, X., and Corsi, R.L., 2006.  "Indoor air quality implications of portable ion generators."  Proceedings of the A&WMA Specialty Conference on Indoor Environmental Quality – Problems, Research, and Solutions, Research Triangle Park, North Carolina (July 2006) 1:1-12.
  33. Siegel J.A., Novoselec, A., and Corsi, R.L., 2006.  “Indoor Environmental Science and Engineering: An Integrated Academic Program.”  Proceedings of the Air and Waste Management Association/Environmental Protection Agency Indoor Air Quality Solutions Conference, Research Triangle Park, North Carolina (July 2006) 8:1-7.
  34. Waring, M.S., Siegel, J.A., and Huang, P., 2006. “An Evaluation of a Smoking Ban Ordinance in Bars in Austin, TXProceedings of Healthy Buildings 2006, Lisbon, Portugal, I, 137-142.
  35. Siegel, J.A., Juenger, M., and Stewart, J., 2006.  “Does the Addition of Fly Ash to Concrete Present a Radon Hazard?”  Proceedings of Healthy Buildings 2006, Lisbon, Portugal, II, 501-506.
  36. Karamalegos, A., Simon, H., Zhao, P., Morrison, G., Siegel, J., and Corsi, R.L., 2005.  “Personal Reactive Clouds: Introducing the concept of near head chemistryIndoor Air 2005: Proceedings of the 10th International Conference on Indoor Air and Climate, II (2005), 2356-2360.  
  37. Fradella, J. and Siegel, J., 2005. “An evaluation of shelter-in-place strategies in four industrial buildingsIndoor Air 2005: Proceedings of the 10th International Conference on Indoor Air and Climate, IV, (2005), 3360-3364.
  38. Zhao, P., Siegel, J. A., and Corsi, R. L., 2005, “Ozone Removal by Residential HVAC Filters: For better or worse” Proceedings of the Air and Waste Management Association 2005 Annual Meeting.
  39. Zhao, P., Siegel, J. A., and Corsi, R. L., 2005.  “Ozone removal by residential HVAC filtersIndoor Air 2005: Proceedings of the 10th International Conference on Indoor Air and Climate, II (2005), 2366-2370.
  40. Mullen, N., Yu, X., Zhao, P., Corsi, R. L., and Siegel, J. A., 2005.  “Experimental Characterization of Portable Ion GeneratorsIndoor Air 2005: Proceedings of the 10th International Conference on Indoor Air and Climate, IV (2005), 2957-2961.
  41. Siegel, J., Schmidt, K., and Cone, J., 2004.  “INTICE - Interactive Technology to Improve the Classroom Experience.”  Proceedings of the 2004 American Society for Engineering Education Annual Conference & Exposition (2004), 2531-2542.
  42. Siegel, J. and Walker, I., 2003.  “Integrating Ducts into the Conditioned Space: Successes and Challenges.”  Building Integration Solutions: Proceedings of the Architectural Engineering 2003 Conference, 1-9.
  43. Ward, M., Siegel J., and Corsi, R., 2003, “Stand Alone Air Cleaners: Evaluation and Implications.”  Proceedings of the Air and Waste Management Association/Environmental Protection Agency Indoor Air Quality Solutions Conference, Research Triangle Park, North Carolina (July 2003) 1:1-9.
  44. Siegel, J., Walker, I., and Sherman, M., 2002.  “Dirty Air Conditioners: Energy Implications of Coil Fouling.”  Proceedings of the 2002 ACEEE Summer Study on Energy Efficiency in Buildings, 1 (2002), 287-300.
  45. Siegel, J. and Nazaroff W.W., 2002, “Modeling Particle Deposition on HVAC Heat Exchangers” in Indoor Air 2002: Proceedings of the 9th International Conference on Indoor Air and Climate, I (2002), 521-526.
  46. Siegel, J. and Walker, I., 2001, “Deposition of Biological Aerosols on HVAC Heat Exchangers” ASHRAE IAQ 2001: Moisture, Microbes, and Health Effects: Indoor Air Quality and Moisture in Buildings, 1-9.
  47. Siegel, J. and Carey, V.P., 2001, “Fouling of HVAC Fin and Tube Heat Exchangers” in Heat Exchanger Fouling: Fundamental Approaches & Technical Solutions, 4th International conference of fouling, 425-433.
  48. Siegel, J., Walker, I., and Sherman, M., 2000, "Delivering Tons to the Register: Energy Efficient Design and Operation of Residential Cooling Systems" in Proceedings from the 2000 ACEEE Summer Study on Energy Efficiency in Buildings, 1 (2000), 295-306.
  49. Siegel, J., Davis, R., Francisco, P., and Palmiter, L., 1998, "Measured Heating System Efficiency Retrofits in Eight Manufactured (HUD Code) Homes" in Proceedings from the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, 2(1998), 189-201.
  50. Walker, I., Siegel, J., Brown, K., and Sherman, M., 1998, "Saving Tons at the Register" in Proceedings from the 1998 ACEEE Summer Study on Energy Efficiency in Buildings, 1(1998), 367-385.


Other

Rosenthal, J. and Siegel, J.A. 2009. Letter to the Editor: Does filter media type really affect BRS? Indoor Air, 19(4), 346-347.

Dissertation (Copyright Jeffrey Siegel, contact me for permission to use or distribute)

Siegel, J. 2002. Particulate Fouling of HVAC Heat Exchangers. Department of Mechanical Engineering at the University of California at Berkeley. (Note that this is a 2.2 MB download)

Students Coming Soon

Last Modified 12/07/2011